The standard SH2 dual axis sample mounting module has a relative magnetic permeability of <1.005, making the ideal choice for low energy experimentation.


联系电话:

021-58997868

Features

Relative permeability is <1.005

Low swept volume

Samples of varying thickness can be rotated on axis

Standard Sample axial Offset, 9 to 12mm (without heater)

Sample axial offset with SH1E50 option 9 to 50mm (without heater)

Primary (R1) Rotation with no services 360°

Primary (R1) Rotation With services i.e.heating and cooling ±180°

Swept Radius from 25mm to 38mm depending on additional modules being selected

Residual Magnetism 10 milli Gauss

Azimuthal (R2) rotation ±110°

Accepts the following options

Resistive heater (HST) 950°C option

EB heater (EBH) 1200°C option

Cooling (ZLN) -160°C option

14mm plain accessory where heating/cooling is not required

25mm plain accessory where heating/cooling is not required

http://cache.cyclerack.net/ibwdfejq19/960x3000_fit.jpg

The SH2 provides one axis of rotation about the centre of the manipulator and the second at 90° known as azimuthal rotation.

Two different offset positions available;

a) The SH2E50 will provide move the sample away from the centre axis,

b) The SH2R64 moves the sample position 64mm above the central axis.

As with all the manipulation range, this module is fully compatible for both the heating and cooling modules making it the perfect multidiscipline two axis sample mounting module.

Note: totally non-magnetic version are available

Two different offset positions available;

a) The SH2E50 will provide move the sample away from the centre axis,

b) The SH2R64 moves the sample position 64mm above the central axis.

As with all the manipulation range, this module is fully compatible for both the heating and cooling modules making it the perfect multidiscipline two axis sample mounting module.

Note: totally non-magnetic version are available

http://cache.cyclerack.net/vacgi51pd9h90/664x825_center.jpg

Sample Holders - Basic Specifications

SH1SH1E50SH2SH2E50SH2R64SH2FSH2RTSM2TSM2VT
Rotary Drive RequiredRD1RD1RD2RD2RD2RD224RD2RD2RD2
Primary (R1) Rotation








No services360°360°360°360°360°360°360°360°360°
With services±180°±180°±180°±180°±180°±180°±180°±180°±180°
Azimuthal (R2) Rotation








Preset±180°±180°






Variable

±110°±110°±110°±180°


Tilt (R3) Rotation





±110°±10°±10°
Sample OffsetEEEEREEEE
Bare backplate (mm)9 to 129 to 509 to 129 to 5054 to 649 to 125.5 to 9.55.5 to 7.55.5 to 7.5
Plain or heater unit (mm)0 to 30 to 410 to 30 to 4160 to 660 to 30 to 2.50 to 2.50 to 2.5
Swept Radius
From
From




No services (mm)2525 (min)2525 (min)54 to 64253135
With all services (mm)3838 (min)3838 (min)54 to 643844VariableVariable
Magnetic PermeabilityLowLowLowLowLowLowLowNormalNormal
'H' dimension (mm)6666666666103666666
Temperature Ranges








Resistive heater (HST)950 °C950 °C950 °C950 °C950 °C950 °C950 °C950 °C950 °C
EB heater (EBH)1200 °C1200 °C1200 °C1200 °C1200 °C1200 °C1200 °C1200 °C1200 °C
Cooling (LN)-160 °C-160 °C-160 °C-160 °C-140 °C-160 °C-160 °C-160 °C-160 °C
Approx. resolution per
halfstep of RD motor









R1 rotation (stepper)0.01°0.01°0.01°0.01°0.01°0.01°0.01°0.01°0.01°
R2 rotation (stepper)--0.001°0.001°0.001°0.001°---
R3 rotation (stepper)------0.001°0.0001°0.0001°



产品参数